did
int64 0
1.04k
| query
stringlengths 5
943
| name
stringlengths 1
71
| duplicate_id
int64 0
671
| metalabel
int64 1
37
|
---|---|---|---|---|
800 |
Classification of explosion-proof electrical equipment according to their maximum surface temperature for use in explosive atmospheres according to (IEC 50(426):1990
|
Explosionprotection temperature class of electric motor
| 432 | 1 |
801 |
Constructive measures for electrical equipment to prevent the ignition of a surrounding potentially explosive atmosphere
|
Explosion protection Type of protection of the electric motor
| 433 | 1 |
802 |
Standardized identification of the type of ignition protection to be used or the hazardous environment of an equipment operation
|
Ex- protection label
| 434 | 1 |
803 |
(official) designation for a natural or legal person who is responsible for the design, manufacture and packaging as well as the labeling of the seal with a view to placing it on the market on his own behalf, regardless of whether these activities are carried out by this person or on his behalf by a third person
|
man. name of sealing
| 435 | 1 |
804 |
common name of material of can
|
designation of the material of the can
| 436 | 1 |
805 |
The course of the resistive torque (load torque) of the driven machine in relation to the motor shaft as a function of speed
|
drive load moment
| 437 | 7 |
806 |
Indicates whether a manufacturer's declaration is available for the product
|
man. Declaration avail.
| 438 | 25 |
807 |
indicates whether the object has equipment with which heating or cooling is possible
|
heating/cooling avail.
| 439 | 25 |
808 |
country in which the manufacturer ist legally registered
|
Producer country
| 440 | 7 |
809 |
uniqui combination of characters in order to identify an order
|
Man. order code
| 441 | 7 |
810 |
Designation of a manufacturer's list within all individual parts required for the production or assembly of a product are named
|
Manufacturer parts list number
| 442 | 1 |
811 |
number which is linked to a document with drawings
|
draw. num. of manufacturer
| 443 | 1 |
812 |
guideline for determining conformity
|
declaration of conformity
| 444 | 1 |
813 |
The maximum length-wise expansion of the base plate
|
base plate length
| 445 | 19 |
814 |
The maximum height-wise expansion of the base plate
|
base plate length
| 446 | 19 |
815 |
the largest radial enveloping dimension of the impeller
|
Outer diameter of impeller
| 447 | 19 |
816 |
largest extension of the height
|
height (overall)
| 448 | 19 |
817 |
largest extension of the length
|
length (overall)
| 449 | 19 |
818 |
internal volume of a pressure chamber up to the first flange connection, excluding the volume of internal parts
|
fill vol (equip)
| 450 | 19 |
819 |
mechanical resistance before movement of the actuator
|
init. breakaway torque (actuator)
| 451 | 19 |
820 |
Commonly used name or trade name of the material of the coating in room 1
|
coating material designation (room1)
| 452 | 1 |
821 |
everyday language name for the material of the containment shroud
|
containment can material name
| 453 | 1 |
822 |
Usual name of the material of the drive housing in general language
|
drive housing material name
| 454 | 1 |
823 |
common material name of the plain bearing sleeve
|
name of the material of plain bearing bush
| 455 | 1 |
824 |
Usual name or brand name of the material of the casing in general language
|
name of material of housing
| 456 | 7 |
825 |
commonly designation of the material of dynamic seal
|
dynamic seal material name
| 457 | 1 |
826 |
Commonly used name or trade name of the substance or mixture of substances which is pumped
|
pumped medium designation
| 458 | 1 |
827 |
designation of the material which was used to produce the auxiliary seal
|
auxiliary seal material name
| 459 | 1 |
828 |
everyday language name for the material of the shaft
|
name of material of shaft
| 460 | 1 |
829 |
Commonly used name or trade name of the material of the shaft protection sleeve
|
shaft protection sleeve material designation
| 461 | 1 |
830 |
Usual name of the material of the static seal in general language (housing)
|
static seal housing material name
| 462 | 1 |
831 |
Commonly used name or trade name of the material of the stator
|
Stator material designation
| 463 | 1 |
832 |
Classification of Explosion-proof pump
|
EPL Explosion of pump
| 464 | 1 |
833 |
Characterization of hazardous gaseous substances based on their ability to cause an explosion
|
explosion protection group of electric drive
| 465 | 1 |
834 |
Classification of Explosion-proof electric drive
|
EPL Explosion of electric drive
| 466 | 1 |
835 |
characterization of ability of gas to cause an explosion
|
pump ex prot group
| 467 | 1 |
836 |
construction measures that ensure, that ignition is prevented
|
Type of pump ignition protection
| 468 | 1 |
837 |
classification of explosion-proof electrical equipment based on its maximum surface temperature (use in potentially explosive atmosphere)
|
temperature class of pump (ex-protection)
| 469 | 1 |
838 |
equipment classification according to the place of use and the cause of the hazard
|
device group of pump (ex-protection)
| 470 | 1 |
839 |
marking of explosion protection according to directive 94/9/EC
|
marking of explosion protection of the pump
| 471 | 1 |
840 |
Classification determined by the safety level of the device
|
pump category for explosion protection
| 472 | 1 |
841 |
Use of a Universal Resource Identifier (URI) for the unique global identification of the object within an installation
|
identification of a plants object
| 473 | 1 |
842 |
name of the material of the stator tube
|
stator tube material name
| 474 | 1 |
843 |
Commonly used name or trade name of the material of the impeller
|
Impeller material name
| 475 | 1 |
844 |
a clearly descritption by using a numbering of materials based in standards
|
can material number
| 476 | 1 |
845 |
standard-based coding of materials of dynamic seal
|
dynamic seal material key
| 477 | 1 |
846 |
a clearly descritption of the material of the coating by using a numbering of materials based in standards
|
mat numb of coating (room 1)
| 478 | 1 |
847 |
Standards-based material coding (containment can)
|
mat numb of containment can
| 479 | 1 |
848 |
a clearly description of the material of the drive housing by using a numbering of materials based in standards
|
mat numb of drive housing
| 480 | 1 |
849 |
A norm-based numbering of the materials. The material is unambiguously described by referring to a norm
|
mat numb of plain bearing brush
| 481 | 1 |
850 |
a clearly descritption of the material of the housing by using a numbering of materials based in standards
|
housing material number
| 482 | 7 |
851 |
number code of different materials of dynamic seals which are based on standars
|
dynamic seal material number
| 483 | 1 |
852 |
a clearly description of the pumped medium by using a numbering of substances based in standards
|
pumped medium substance code
| 484 | 1 |
853 |
a clearly description of the auxaliary seal by using a numbering of materials based in standards
|
material code for auxiliary seal
| 485 | 1 |
854 |
a clearly description of the shaft by using a numbering of materials based in standards
|
number of material of shaft
| 486 | 1 |
855 |
a clearly description of the shaft protection sleeve by using a numbering of materials based in standards
|
number of material of shaft protection sleeve
| 487 | 1 |
856 |
a clearly description of the static seal housing by using a numbering of materials based in standards
|
static seal housing material code
| 488 | 1 |
857 |
norm-based coding of the material of the stator
|
Stator material code
| 489 | 1 |
858 |
a clearly description by using a numbering of materials based in standards
|
stator tube material number
| 490 | 1 |
859 |
a clearly description of the impeller by using a numbering of materials based in standards
|
Impeller material code
| 491 | 1 |
860 |
manufacture country of the product
|
manufacture country of product
| 492 | 1 |
861 |
Quantitative quantity of levels represented by natural numbers
|
count of levels
| 493 | 31 |
862 |
standard describing the material and material number. The type and number of the standard with the year and month of issue must be indicated.
|
Reference standard of the material (coating, space 1)
| 494 | 1 |
863 |
standard describing the material and material number. The type and number of the standard with the year and month of issue must be indicated.
|
Reference standard of the shaft material
| 495 | 1 |
864 |
standard describing the material and material number. The type and number of the standard with the year and month of issue must be indicated.
|
Reference standard of the material of the drive housing
| 496 | 1 |
865 |
standard describing the material and material number. The type and number of the standard with the year and month of issue must be indicated.
|
Reference standard of the can material
| 497 | 1 |
866 |
reference parameter with informative value about mechanical and dimensional properties of a pipe component
|
PN of muffs (A1)
| 498 | 1 |
867 |
reference parameter with informative value about mechanical and dimensional properties of a pipe component
|
PN of muffs (A2)
| 499 | 1 |
868 |
Nominal size is an alphanumeric designation of size for components in a piping system for reference. (A1)
|
DN of muffs (A1)
| 500 | 1 |
869 |
Nominal size is an alphanumeric designation of size for components in a piping system for reference. (A2)
|
DN of muffs (A2)
| 501 | 1 |
870 |
describes the degree of protection of an electric motor against ingress of foreign objects and water
|
electric motor - protection type class
| 502 | 1 |
871 |
Continuous, short-term or intermittent duty characterized by one or more loads that remain unchanged over a period of time, or non-periodic duty where the load and speed vary generally within the allowable operating range
|
Timing of the operating mode of the drive
| 503 | 7 |
872 |
DUNS number, supplier number or other number to identify a provider or supplier of the identification number
|
D-U-N-S-Number
| 504 | 1 |
873 |
the then version of the standard to which reference was made
|
reference norm
| 505 | 1 |
874 |
the corresponding standard where the material code is defined
|
reference norm for material of the housing
| 506 | 1 |
875 |
Difference between absolute pressure and atmospheric pressure. For this purpose, the overpressure for a pressure chamber can be in a vacuum, for example.
|
max. overpressure (shaft seal)
| 507 | 19 |
876 |
Vom Hersteller festgelegter Höchstwert des Betriebsüberdruckes PS1+ bezogen auf den Atmosphärendruck bei maximal zugelassener Betriebstemperatur TS1
|
the maximum permissible overpressure (PS1+ at TS1, room 1)
| 508 | 19 |
877 |
Maximum value of the operating vacuum PS2- specified by the manufacturer in relation to the atmospheric pressure at the maximum permissible operating temperature TS2
|
the maximum permissible negative pressure (PS2- for TS2, room 1)
| 509 | 19 |
878 |
Maximum value of the operating vacuum PS2- specified by the manufacturer in relation to the atmospheric pressure at the maximum permissible operating temperature TS2
|
the maximum permissible negative pressure (PS2- for TS2, room 2)
| 510 | 19 |
879 |
The maximum value of the operating vacuum PS1- specified by the manufacturer in relation to the atmospheric pressure at the maximum permissible operating temperature TS1
|
the maximum permissible negative pressure (PS1- at TS1, room 1)
| 511 | 19 |
880 |
The maximum value of the operating vacuum PS1- specified by the manufacturer in relation to the atmospheric pressure at the maximum permissible operating temperature TS1
|
the maximum permissible negative pressure (PS1- at TS1, room 2)
| 512 | 19 |
881 |
Maximum value of the operating vacuum PS2+ specified by the manufacturer in relation to the atmospheric pressure at the maximum permissible operating temperature TS2
|
the maximum permissible overpressure (PS2+ at TS2, room 1)
| 513 | 19 |
882 |
Maximum value of the operating vacuum PS2+ specified by the manufacturer in relation to the atmospheric pressure at the maximum permissible operating temperature TS2
|
the maximum permissible overpressure (PS2+ at TS2, room 2)
| 514 | 19 |
883 |
Maximum value of the operating vacuum PS1+ specified by the manufacturer in relation to the atmospheric pressure at the maximum permissible operating temperature TS1
|
the maximum permissible overpressure (PS1+ at TS1, room 2)
| 515 | 19 |
884 |
Maximum outer diameter of a pump impeller for a specific pump housing
|
the maximum permissible outside diameter of the impeller
| 516 | 19 |
885 |
minimum outer diameter of a pump impeller for a specific pump housing
|
the minimum permissible outside diameter of the impeller
| 517 | 19 |
886 |
nominal value of the net positive suction head at maximum flow rate
|
NPSH at max. flow rate
| 518 | 19 |
887 |
nominal value of the net positive suction head at minimum flow rate
|
NPSH at min. flow rate
| 519 | 19 |
888 |
minimum density of the liquid at design temperature (mass by volume). The unit used must be listed. The reference temperature is 15°C. This may vary for special purposes.
|
the minimum density at design temperature
| 520 | 19 |
889 |
maximum density of the liquid at design temperature (mass by volume). The unit used must be listed. The reference temperature is 15°C. This may vary for special purposes.
|
the maximum density at design temperature
| 521 | 19 |
890 |
Number of revolutions divided by the corresponding time
|
the maximum speed of the drive
| 522 | 13 |
891 |
Number of revolutions divided by the corresponding time
|
the minimum speed of the drive
| 523 | 13 |
892 |
speed in the rated state
|
Measuring speed of the electric motor
| 524 | 13 |
893 |
Number of revolutions divided by the corresponding time
|
rated speed of the drive
| 525 | 13 |
894 |
largest value of the ratio of applied shear stress to shear rate. The dynamic viscosity η (η= "Eta") is a measure of the viscosity of a fluid
|
the maximum dynamic viscosity at design temperature
| 526 | 19 |
895 |
lowest value of the ratio of applied shear stress to shear rate. The dynamic viscosity η (η= "Eta") is a measure of the viscosity of a fluid
|
the minimum dynamic viscosity at design temperature
| 527 | 19 |
896 |
Rated power at operating conditions specified by the manufacturer
|
rated output of the electric motor
| 528 | 19 |
897 |
lowest value of the mechanical power requirement of the pump at any flow rate, under any permissible working conditions
|
min. pump power requirement
| 529 | 19 |
898 |
voltage specified by the manufacturer, which results from measured values under certain circumstances
|
Electric motor measured tension
| 530 | 19 |
899 |
Minimum temperature of the material that must not be fallen below in order to prevent changes in the material properties
|
work temperature (lower limt)
| 531 | 19 |
Subsets and Splits
No community queries yet
The top public SQL queries from the community will appear here once available.